03301-L Wind Sentry Vane
Reliable, Accurate Wind Direction
Sensor for only measuring wind direction
météorologie : eau : energie : gaz & flux turbulents : infrastructure : terre :

Aperçu

The 03301, manufacted by R. M. Young, is the wind vane included with our Wind Sentry Sets (03002, 03001). Although some customers have valid applications that require monitoring wind speed only (without direction), monitoring wind direction only (without wind speed) provides little useful information. For this reason, the 03301 is available for two purposes:

  1. As a replacement vane for a Wind Sentry Set that requires replacement of the vane only
  2. As an "upgrade" for a customer that originally purchased only the anemometer and now wants to add the vane to make a complete Wind Sentry Set

Images

Compatibilité

Veuillez noter : Ce qui suit montre des informations de compatibilité générales. Ce n'est pas une liste complète de tous les produits compatibles.

Centrale de mesure

Produits Compatibilité Note
CR1000 (obsolète)
CR1000X
CR300 (obsolète)
CR3000 (obsolète)
CR310
CR350
CR6
CR800 (obsolète)
CR850 (obsolète)

Informations de compatibilité supplémentaires

Data Logger Considerations

The wind vane is measured by the BrHalf Instruction in CRBasic, and by Instruction 4 (Excite-Delay-SE) in Edlog.

Spécifications

Sensor Vane
Measurement Description Wind direction
Operating Temperature Range -50° to +50°C (assuming non-riming conditions)
Mechanical Range 360°
Electrical Range 352° (8° open)
Sensor Balanced vane; 16 cm turning radius
Accuracy ±5°
Damping Ratio 0.2
Delay Distance 0.5 m (1.6 ft ) 50% recovery
Starting Threshold
  • 0.8 m s-1 (1.8 mph) with 10° displacement
  • 1.8 m/s (4 mph) with 5° displacement
Transducer
  • Precision conductive plastic potentiometer (10 kohm resistance)
  • 1.0% linearity
  • Life expectancy is 50 million revolutions.
  • Rated 1 W at 40°C, 0 W at 125°C.
Transducer Excitation Requires regulated dc voltage (15 Vdc maximum)
Transducer Output Analog dc voltage proportional to wind direction angle with regulated excitation voltage supplied by the data logger
Vane Length 22 cm (8.7 in.)
Weight 170 g (6 oz)


FAQ

Nombre de FAQ au sujet de(s) 03301-L: 3

Développer toutRéduire tout

  1. The wind vane does not use bearings, so replacement is not necessary. Typically, the part that needs replacing is the potentiometer. Campbell Scientific recommends factory replacement.

    1. En utilisant Short Cut, cliquez sur une des girouettes proposées dans la liste Selected Sensors de l'écran Outputs.
    2. Deux options de sortie sont disponibles : Sample (échantillon) et WindVector (Vecteur vent). Selectionnez WindVector.
    3. L'instruction du vecteur vent  WindVector a diverses options de sortie. Selectionnez une des options avec la direction moyenne du vent.