The A6REL-12 has six internal relays for controlling up to 12 external AC or DC devices. Each relay set can be controlled manually or by a datalogger.
Lire la suiteThe A6REL-12's internal relays are dual single-pole double-throw. Each of the six relays has a three position toggle switch; "on" and "off" for manual override, and "auto" for datalogger control. In the on position, the common and normally open contacts are shorted. In the auto position, the state of a relay is controlled by a datalogger control port.
A6REL-12's with serial numbers 1445 and higher are UL-approved.
Veuillez noter : Ce qui suit montre des informations de compatibilité générales. Ce n'est pas une liste complète de tous les produits compatibles.
Produits | Compatibilité | Note |
---|---|---|
CR1000 (obsolète) | ||
CR200X (obsolète) | ||
CR216X (obsolète) | ||
CR3000 (obsolète) | ||
CR5000 (obsolète) | ||
CR800 (obsolète) | The CR800 has only four control ports capable of providing a control signal. | |
CR850 (obsolète) | The CR850 has only four control ports capable of providing a control signal. | |
CR9000X (obsolète) |
Produits | Compatibilité | Note |
---|---|---|
ENC10/12 | ||
ENC12/14 | ||
ENC14/16 | ||
ENC16/18 | ||
ENC24/30 | ||
ENC24/30S |
Each of the six relays is controlled by a datalogger control port.
Cable(s) Used | Number of Relays Controlled |
One CABLE3CBL-L | 1 |
One CABLE4CBL-L | 2 |
One CABLE5CBL-L | 3 |
Two CABLE3CBL-L | 4 |
One CABLE3CBL-L and one CABLE4CBL-L |
5 |
Two CABLE4CBL-L | 6 |
The A6REL-12 consumes 30 mA per active LED. The A6REL-12 may be powered by the datalogger power supply (see manual for considerations with 21X) or a separate 8.4 to 24 Vdc battery. The A6REL-12 must be powered by a Class 2 device (Campbell Scientific power supplies conform to this requirement).
The A6REL-12 requires a non-condensing environment; a Campbell Scientific enclosure is recommended. A6REL-12's with serial numbers 1445 and higher include mounting flanges with keyhole slots that attach to the backplate of an enclosure. Grommets and screws are provided.
A6REL-12s with serial numbers 1444 and lower require the 6281 bracket kit for attachment to the backplate of Campbell enclosures.
Function | Controls up to 12 external ac or dc devices. |
Nombre de voies | 6 |
Operating Voltage | 12 Vdc nominal (8.4 to 24 Vdc) |
Current Drain at 12 Vdc |
|
Toggle Switch | ON/OFF manual override; AUTO for data logger control |
Relays | dual single pole double throw, break before make |
Contact Material | Gold-clad silver |
Coil Resistance | 720 Ω ±10% |
Contact Ratings |
|
Release/Actuation Time | ~3 ms |
Operating Temperature | -40° to +70°C |
Standards |
|
Dimensions | 22.4 x 13.9 x 4.1 cm (8.8 x 5.5 x 1.6 in.) including switches and mounts |
Weight | 635 g (1.4 lb) |
Expected Life (contact closures) |
|
Mechanical | 108 |
Electrical |
|
Nombre de FAQ au sujet de(s) A6REL-12: 2
Les modules à relais ci-dessous peuvent être utilisés avec la CR800 et la CR850 :
Les centrales de mesure CR800 et CR850 peuvent également être utilisées avec une grande variété de dispositifs de relais.
Oui. Le CR1000 est entièrement programmable pour commander ou envoyer des alarmes. La CR1000 peut effectuer des envois à distance d'un message électronique, d’un SMS ou d’un texte, envoyer un message vocale, ou en appelant un pager. La CR1000 peut également activer des alarmes physiques telles que des sirènes et des gyrophares. Dans ce type d'installation, un dispositif de relais, tel que LR4, est généralement utilisé pour envoyer un signal de commande pour le dispositif d'alarme.