HMP60-ET Temperature/RH Probe for ET Station
Accurate, Rugged
Ideal for long-term, unattended applications
météorologie : eau : energie : gaz & flux turbulents : infrastructure : terre :

Aperçu

The HMP60-ET, manufactured by Vaisala, is the replacement temperature and RH sensor for older ET stations. The sensor's cable terminates in a connector and is the ideal length for attachment to the ET107 or ET106 ETo Weather Station. 

The HMP60-ET measures both temperature and relative humidity and is suitable for long-term, unattended monitoring. The humidity component features a field-replaceable chip, which eliminates downtime typically required for the recalibration process.

For an existing ET station with an R. M. Young radiation shield, use a new HMP60-ET with an old sensor adapter that is in usable condition. (The HMP60-ET does NOT ship with any adapter.) If the old adapter cannot be reused, contact Campbell Scientific for assistance in selecting an appropriate option. It may be necessary to replace the entire radiation shield.

Lire la suite

Images

Description technique

The HMP60-ET uses the INTERCAP® capacitive RH chip. This chip is field-replaceable, which eliminates the downtime typically required for the recalibration process.


Compatibilité

This sensor is compatible with older ET107, T107, and WSPRO2 stations and retired ET stations such as the ET106, T106, and WSPRO.

Spécifications

Supply Voltage 5 to 28 Vdc (typically powered by datalogger’s 12 V supply)
Typical Current Consumption 1 mA
Maximum Current Consumption 5 mA
Filter Description 0.2 µm Teflon membrane
Settling Time 1 s
Sensor Body Material AISI 316 stainless steel
Filter Cap Material Chrome-coated ABS plastic
Classification IP65
Filter Diameter 1.2 cm (0.5 in.)
Sensor Diameter 1.2 cm (0.5 in.)
Sensor Length 7.1 cm (2.8 in.)
Cable Length 137.16 cm (54 in.)
Weight 90.72 g (0.2 lb)

Temperature

Temperature Sensor 1000 ohm Platinum Resistance Thermometer
Measurement Range -40° to +60°C
Accuracy ±0.6°C

Relative Humidity

Sensor Vaisala’s INTERCAP capacitive chip
Measurement Range 0 to 100% RH (non-condensing)
Accuracy (0 to 90% RH)
  • ±5% (-40° to 0°C)
  • ±3% (0° to 40°C)
  • ±5% (40° to 60°C)
Accuracy (90 to 100% RH)
  • ±7% (-40° to 0°C)
  • ±5% (0° to 40°C)
  • ±7% (40° to 60°C)


FAQ

Nombre de FAQ au sujet de(s) HMP60-ET: 1

  1. De nombreux capteurs Campbell Scientific sont disponibles avec différentes options de terminaison de câble. Ces options comprennent les éléments suivants :

    • Par défaut le câble du capteur se termine par des fils étamés, qui se connectent directement au bornier d'un multiplexeur ou d'une centrale de mesure.
    • Vous pouvez choisir d'avoir un connecteur qui se fixera sur une embase sur votre coffret pré-câblé, dans ce cas il faut prendre l'option 03C (référence : 009384) ou 02C (on utilisera un connecteur 02C (référence : 009551) pour un panneau solaire par exemple).
    • Certains systèmes de mesure comme le CS110, les stations météorologiques ET107 ou l'ET106 ont des connecteurs spéciaux.
    • Pour les capteurs sans fil de la série CWS (il existe des connecteurs pour le module CWS900E en option), cela permet de connecter un capteur à l'interface sans fil CWS900E.

    Note : La disponibilité des options de terminaison du câble varie selon le capteur. Par exemple, les capteurs peuvent avoir aucune, deux ou plusieurs options à choisir. Si une option souhaitée n'est pas répertoriée pour un capteur spécifique, contactez Campbell Scientific pour obtenir de l'aide.